U1731B/U1732B Dual Display Handheld LCR Meter User’s and Service Guide Agilent Technologies 1 Getting Started Introduction 2 Checking the Shipping Contents 3 The Front Panel at a Glance 4 Display Annunciators 5 The Keypad at a Glance 7 The Input Terminal at a Glance 8 This chapter introduces the key features and getting-started tips for the. One lcr meter family for your product’s life cycle, Reduce production test factors, Automated quality assurance – Atec Agilent-4284A4285A User Manual Page 6: Research tomorrow’s electronic components now, Design and test new materials.

3

Satisfying your
performance needs

Adapt instrument configurations
to fit your test needs

• Internal voltage biasing up to ±40 Vdc

3

• High current biasing up to 40 A dc

3

(Agilent 4284A)

• Wide range of frequencies, 20 Hz to

30 MHz

• BIN’ing and comparator functions for

handlers

• SMD, axial and radial test fixtures

3

Simplify your system
development and integration

• Programming language compatible

with IEEE 488.2

• Test port extensions: maximum 4 m

for 4284A

3

and 2 m for 4285A

• Identical operation for the entire

family of products

• Scanner, handler and GPIB interfaces

3

Key specifications

Agilent 4285A precision LCR meter

Test frequency

75 kHz to 30 MHz with 100 Hz resolution

Measurement range

1

Z , R, X :0.01 m

Ω to 99.9999 MΩ

Y , G,B :0.01 nS to 99.9999 S

C :0.01 fF to 999.999 µF
L :0.001 nH to 99.9999 H
D :0.000001 to 9.99999
Q :0.01 to 99999.9

Basic accuracy

Z , C and L:0.1% D:0.001

Test signal level range

Voltage

5 mVrms to 2 Vrms

Current

200 µArms to 20 mArms

Constant test signal level range

Voltage

10 mVrms to 1 Vrms

Current

100 µArms to 20 mArms

Measurement time

2

30 ms/65 ms/200 ms

4285A with Option 4285A-001

Internal DC bias

± (1 mV ~ 40 V),

≤ 100 mA, 0.1% accuracy

4285A with Option 4285A-002, 42841A, and 42842C

DC current bias

0.01 A to 10 A

1. Refer to specifications for complete accuracy.
2. Supplimental information only.
3. The options, the accessories, or the test fixtures

are needed.

Advertising
Popular Brands
Popular manuals

Page 2: Move your process toward error-free operation, Agilent 4284a precision lcr meter

Advertising

2

Agilent
precision LCR meter family

Utilize state-of-the art
measurement technologies

• 6-digits of resolution at any range

• Basic accuracies of

0.05% (Agilent 4284A) and

0.1% (Agilent 4285A)

• 20 impedance parameters to access

and measure

• Constant V or I test signal level

• 20 Vrms test signal level

(Agilent 4284A)

Move your process toward
error-free operation

• Instrument setup state storage

• Comparator functions

• Selectable frequency error

Agilent 4284a Lcr Meter User Manual

corrections

Hp 4284a Precision Lcr Meter

• Open, short and load corrections

remove parasitics

Key specifications

Agilent 4284A precision LCR meter

Test frequency

20 Hz to 1 MHz over 8610 selectable frequencies

Measurement range

1

Z , R, X :0.01 m

Ω to 99.9999 MΩ

Y , G,B :0.01 nS to 99.9999 S

C :0.01 fF to 9.99999 F
L :0.01 nH to 99.9999 kH
D :0.000001 to 9.99999
Q :0.01 to 99999.9

Agilent 4284a Lcr Meter Manual

Basic accuracy

Z , C and L:0.05% D:0.0005

Test signal level range

Voltage

5 mVrms to 2 Vrms

Current

50 µArms to 20 mArms

Constant test signal level range

Voltage

10 mVrms to 1 Vrms

Current

100 µArms to 10 mArms

Measurement time

2

39 ms/190 ms/830 ms at 1 kHz

4284A with Option 4284A-001

Test signal level range

Voltage

5 mVrms to 20 Vrms

Current

50 µArms to 200 mArms

Constant test signal level range

Voltage

10 mVrms to 10 Vrms

Current

100 µArms to 100 mArms

Internal DC bias

± (1 mV ~ 40 V),

≤ 100 mA, 0.1% accuracy

4284A with Option 4284A-002 and 42841A

DC current bias

0.01 A to 20 A (with 42841A and 42842A)
0.02 A to 40 A (with 42841A x 2 ea., 42842B and 42843A)

1. Refer to specifications for complete accuracy.
2. Supplimental information only.